Chimney Systems for Commercial Application

Condensor is a high quality stainless steel single wall system chimney designated as suitable for use with all gas, oil, pellet, wood and coal burning appliances, whether these are atmospheric, pressure-jet, or fully condensing. It is ideally suited for cascade systems for multiple boilers allowing a connection into a common header and comes with a 10 year Axa backed guarantee.

This continuously welded flue provides a pressure and moisture resistant system when used with the optional Joint Seal, for applications requiring pressure tightness up to 200 Pa.

All of the products offered by Cheminées Poujoulat have been rigorously tested in every configuration by the CERIC Laboratory to ensure they meet highest standards (Building Regulation Document J).

It comes with a comprehensive range of standard accessories to suit all applications and environments.

Also available in factory finish painted to any RAL colour.

Condensor can also be used as a liner and/or a connecting pipe. For more details refer to our Condensor Domestic Range

CE marking: 0071-CPD-0047

Designation (Ø80 to Ø150): T250 N1 W V2 L50040 O50 - T200 P1 W V2 L500040 O50 (with Joint Seals)

Designation (Ø180 to Ø300): T250 N1 W V2 L50060 O50 - T200 P1 W V2 L500060 O50 (with Joint Seals)

Designation (Ø350 to Ø600): T250 N1 W V2 L50080 O50 - T200 P1 W V2 L500080 O50 (with Joint Seals)


  • Exceptionally high resistance to corrosion
  • Excellent performance
  • Wide range of Engineered components i.e. Reducing Tees, inspection components
  • Adaptor solution to suit all appliances outlets
  • Quick and easy to install
  • Good looking chimney
  • Easily meets regulation requirements

 

logo CE logo_CERIC.png

Max. Temperature limitation:

- Soot fire tested at 1000
- Operating temperature 450°C

Product overview


Condensing Application

Condensor can be used under positive pressure and suitable for condensing applications, by using a double lip silicone seal which ensures a perfect watertight joint. These seals must be purchased separately and fitted on site by a professional installer

Cascade Systems






The Condensor System Chimney provides cascade solutions for multiple boilers allowing a connection into a common inclined (5º) header, with a vertical flue connection, utilizing 95º Reducing Tee and the Poujoulat non-return valve, on each connection, providing isolation to non-operating boilers.


Technical features

Inner Ø (in mm)

80

100

130

150

180

200

250

300

350

400

450

500

600

Outer Ø (in mm)

91

111

141

161

191

211

261

311

361

411

461

511

611

Wall material

AISI 316L stainless steel

Wall Thickness

0.4 mm

0.6 mm

0.8 mm

Note: Condensor can also be used as a liner and/or a connecting pipe. For more details refer to our Condensor Domestic Range

Finishes

Condensor Single wall chminey (PDF - 998 Ko)

Design

Our Technical team will provide you a full thermal and structural design and produce working CAD drawings, all fully compliant with British and European Standards. We provide as well, Clean Air Act calculation plus ADMS4 dispersion modelling. For any technical enquiries, please e-mail: technical@poujoulat.co.uk

Manufacture

170,000 m² of Group facilities, a skilled work force, state of the art tooling, and continual quality assessment, innovative and quality fabrication is our norm with a stock holding second to none.

Installation

Our highly qualified trained installers arrive on time, fully equipped and prepared and carry out a competent quality installation to your satisfaction, whilst complying with the Health & Safety requirements of today.

Maintenance

Pro-active maintenance guarantees the optimum life expectancy plus maximises the efficiency. With our maintenance personnel, a pro-active quality service is the standard.

Termination position & heights

For biomass heating appliance (< 70 kW input)

  • Refer to Building Regulation Part J

For biomass heating appliance (> 150 kW input)

  • Refer to Clean Air Act Memorandum (CAAM)

For gas heating appliance (> 70 kW input)

  • Refer to IGEM document

Note: If in doubt, do not hesitate to contact our technical department: technical@poujoulat.co.uk

Technical support

Our Technical team will provide you a full thermal and structural design and produce working CAD drawings, all fully compliant with British and European Standards. For any technical enquiries, please e-mail: sales@poujoulat.co.uk

  • Benefits
    • Exceptionally high resistance to corrosion
    • Excellent performance
    • Wide range of Engineered components i.e. Reducing Tees, inspection components
    • Adaptor solution to suit all appliances outlets
    • Quick and easy to install
    • Good looking chimney
    • Easily meets regulation requirements

     

    logo CE logo_CERIC.png

  • Technical data

    Max. Temperature limitation:

    - Soot fire tested at 1000
    - Operating temperature 450°C

    Product overview


    Condensing Application

    Condensor can be used under positive pressure and suitable for condensing applications, by using a double lip silicone seal which ensures a perfect watertight joint. These seals must be purchased separately and fitted on site by a professional installer

    Cascade Systems






    The Condensor System Chimney provides cascade solutions for multiple boilers allowing a connection into a common inclined (5º) header, with a vertical flue connection, utilizing 95º Reducing Tee and the Poujoulat non-return valve, on each connection, providing isolation to non-operating boilers.


    Technical features

    Inner Ø (in mm)

    80

    100

    130

    150

    180

    200

    250

    300

    350

    400

    450

    500

    600

    Outer Ø (in mm)

    91

    111

    141

    161

    191

    211

    261

    311

    361

    411

    461

    511

    611

    Wall material

    AISI 316L stainless steel

    Wall Thickness

    0.4 mm

    0.6 mm

    0.8 mm

    Note: Condensor can also be used as a liner and/or a connecting pipe. For more details refer to our Condensor Domestic Range

    Finishes

  • Installations instructions

    Condensor Single wall chminey (PDF - 998 Ko)

    Design

    Our Technical team will provide you a full thermal and structural design and produce working CAD drawings, all fully compliant with British and European Standards. We provide as well, Clean Air Act calculation plus ADMS4 dispersion modelling. For any technical enquiries, please e-mail: technical@poujoulat.co.uk

    Manufacture

    170,000 m² of Group facilities, a skilled work force, state of the art tooling, and continual quality assessment, innovative and quality fabrication is our norm with a stock holding second to none.

    Installation

    Our highly qualified trained installers arrive on time, fully equipped and prepared and carry out a competent quality installation to your satisfaction, whilst complying with the Health & Safety requirements of today.

    Maintenance

    Pro-active maintenance guarantees the optimum life expectancy plus maximises the efficiency. With our maintenance personnel, a pro-active quality service is the standard.

    Termination position & heights

    For biomass heating appliance (< 70 kW input)

    • Refer to Building Regulation Part J

    For biomass heating appliance (> 150 kW input)

    • Refer to Clean Air Act Memorandum (CAAM)

    For gas heating appliance (> 70 kW input)

    • Refer to IGEM document

    Note: If in doubt, do not hesitate to contact our technical department: technical@poujoulat.co.uk

    Technical support

    Our Technical team will provide you a full thermal and structural design and produce working CAD drawings, all fully compliant with British and European Standards. For any technical enquiries, please e-mail: sales@poujoulat.co.uk


Chimney systems for Industrial applications


Other Poujoulat sites :


How to install a chimney , a chimney stack ?
How to connect an appliance, and how to line a chimney ?

Cheminées Poujoulat is the specialist in production of metallic chimneys, chimney stacks , accessories for single houses, collective buildings, industrial and offices applications, for new buildings and renovations.
Cheminées Poujoulat offers a wide choice of solutions for flexible and rigid linings, connecting chimneys for all typs of appliances , inserts, wood stove, pellet stove, and boilers. Besides, Poujoulat can offer various solutions to improve the smoke evacuation : smoke extractor fans, warm air distribution, draft regulators, solution for maintening and sweeping the chimneys.